Chimney Leaks – Brownstoners in Brklyn & NY

Chimney and Flat Roof Leaks 

Watch this video to see what thew common problem is on chimneys in Brooklyn and Manhattan

Most chimneys and parapet walls are covered with tar, as a repair, to prevent leaks, however, the tar dries, hardens, and cracks creating fine fissures that expand over time. Water will penetrate these cracks and seep under the roof’s membrane making it appear as though the roof is leaking. Over time the roof will be compromised due to these leaks.

While installing a roof on a Brownstone in Brooklyn, we made a video explaining our technique, to prevent any leaking, by covering the walls and chimney with a Modified Bitumen Rubber Membrane.

Turbo Poly Seal is used in the video below. If you want to save money, then watch this video to see how you can repair any chimney with Turbo Poly Seal.

Watch this video to see how to repair flashing on a chimney with Turbo Poly Seal

Leak Repairs: Modified Bitumen Torch Down – Brooklyn and New York

The best roofing material to use on a flat roof is a 2 Ply Modified Bitumen Torch Down Rubber Roof System. New York and surrounding boroughs have made the installation of new Torch Down roofs illegal, but it can be used to make repairs.

Chimney and Parapet Wall Repairs in Manhattan

The image below shows an example of a chimney that has been covered with a Modified Bitumen Torch Down Rubber Membrane, sealing it permanently. This technique should be applied to all parapet walls and chimneys.

Chimney Flat Roof Leaks - Brownstone Brooklyn and Manhattan chimney transition to flat roof
This image shows a chimney that we have covered with a rubber membrane

Brownstone Roofs in Brooklyn

Below is an image of a group of roofs in Brooklyn. Notice that they are all Modified Bitumen Torch Down Rubber roofs. The one in the foreground, where Erik stands, is the roof that we installed. We used a Torch Down rubber membrane that has embedded ceramic granules to provide protection from UV rays.

The second roof is also a torch down roof; however, it is a plain rubber membrane because it does not have embedded ceramic granules to protect it from UV rays. Instead, this membrane has a painted-on aluminum asphalt coating for protection that is reapplied every 3-5 years.

The 3rd roof from Erik is also an aluminum coated torch down rubber membrane. The 4th roof is black because it is an unprotected torch down membrane, which does not have ceramic granules or coating for UV protection.

Also, notice the chimney to the left of Erik. Both the chimney and parapet walls were smeared with tar. We not only recovered the roof, but we covered the parapet walls and chimney with the Modified Bitumen Torch Down Rubber, as well.

Flat Roofs and Architects

A roof is one of the most expensive components of a building. When architects design buildings, they specify the materials to be used on flat roofs and normally go with the roofing materials they are most familiar with. Most architects will specify EPDM or TPO membranes. An architect’s specifications carry a lot of weight. Therefore, most buildings have one or the other types of roof systems. Although specified, these roofing materials do not provide the best protection. When a roofing system is considered, the cost of the material, its longevity, and its maintenance, all play a role in achieving the best, overall value.

Brownstone Roofs in Brooklyn - Both the chimney and parapet walls were smeared with tar. We not only recovered the roof, but we also covered the parapet walls and chimney with the Modified Bitumen Torch Down rubber
In foreground is a chimney covered with the same membrane as what the roof is. The other chimneys in the background are smeared with tar
Flat Roof Chimneys and Flashing - This chimney had been continually smeared with tar but the leaking continued.
This is a Before image of a leaky chimney

We are preparing a chimney’s surface by scraping off old tar so it can be covered with a rubber membrane.

Flat Roof Chimneys and Flashing - Here we are scraping off the old tar and preparing the chimney to install a rubber membrane.
Scraping off loose tar and preparing the chimney

This chimney has been completely sealed with a Modified Bitumen rubber membrane that has been embedded with white ceramic granules for protection against harmful UV rays.

Chimney has been sealed with white ceramic granules embedded in the Modified Bitumen Rubber membrane.
This is the “after” shot of the chimney. For the next 50 years this chimney will not need any work

4 thoughts on “Chimney Leaks – Brownstoners in Brklyn & NY”

  1. blank

    I must thank you for the efforts you’ve put in writing this website.

    I really hope to see the same high-grade content by you later
    on as well. In fact, your creative writing abilities has motivated me to get my own blog now
    😉

  2. blank

    Oh my goodness! Incredible article dude! Many thanks, However I
    am encountering difficulties with your RSS.
    I don’t know the reason why I am unable to subscribe to it.
    Is there anyone else getting the same RSS problems? Anybody who knows the answer will you kindly respond?
    Thanks!!

  3. blank

    I have noticed you don’t monetize your site, don’t waste your traffic, you can earn additional cash every month.
    You can use the best adsense alternative for any type of website (they approve all websites), for more details simply search in gooogle:
    boorfe’s tips monetize your website

  4. blank

    You’re so interesting! I don’t suppose I have read through anything like that before.
    So great to find someone with genuine thoughts on this subject matter.

    Seriously.. thanks for starting this up. This website is something
    that is needed on the web, someone with a bit of originality!

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top